what height platform requires a guardrail

Fall Protection Trigger Heights - UCOP

As noted, fall protection and trigger heights can be a complex topic and consulting your EH&S staff for assistance is advised. Guardrails Are Required. Guardrails must be provided on all open sides of unenclosed elevated work locations, such as roof openings, open and glazed sides of landings, platforms, runways, ramps,..

What is the Appropriate Height for Fall Protection Railing? - Fall .

When working with rigid materials, like 2x4s or metal tubing, this is pretty cut and dried, but when you're dealing with wire rope, you need to make sure you are . Regardless of whether we're discussing arooftop guardrail system, a portable safety rail system, or a job-made railing the height of the top rail must always be 42..

Building Code Guidelines: Decking Railing Heights, Guards, and .

Feb 17, 2017 . If you decide to construct a guard on a deck low enough that it doesn't require guards, it is up to you as to guard rail height and baluster spacing. However, these guards still must be as strong as guards located higher on decks. It is understood that people will lean against guards, and code requires that..

Section 315 Guardrails - Alberta Labour - Government of Alberta

Jul 1, 2009 . (1) An employer must ensure that a guardrail required by this Code has. (a) a horizontal top member installed between 920 millimetres and 1070 millimetres above the base of the guardrail,. (b) a horizontal intermediate member spaced mid-way between the top member and the base,. (c) vertical members..

OSHA Requirements for Guardrail Compliance | Matt Pittner | Pulse .

Feb 20, 2015 . The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, or ramp. The ends of the rails . For general industry applications, unprotected leading edges at heights of 4 feet or more require the use of guardrail or some other form of fall protection. For construction..

Walking and Working Surfaces

Oct 1, 2009 . using scaffolds, requirements of work platforms, and designing and constructing . Fixed ladders must be fixed, and don't require securing for .. must be 37 inches maximum height. f. Standard Handrail. Securely mount a standard handrail on the wall or partition, enclosing the stairs. It must be between 30..

What is the maximum height for a terrace without a guard rail?

Apr 6, 2016 . The 2012 International Building Code (IBC 2012) generally requires guardrails when the difference in elevation between the upper and lower surfaces is 30 inches or greater. 1013.2 Where required. Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms,..

At What Height is Fall Protection Required? - Fall Protection Blog

This means that at any point your employees are exposed to heights equal to or greater than these, they must have some sort of protection, whether it be fall arrest systems, railings, . It is harder to recognize a fall hazard and have a railing system permanently installed like you might be able to do on a manufacturing floor

Five Key OSHA Standards for Work Platforms - Spika Blog

May 30, 2017 . OSHA 1910.29(b)(1): The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the . If you need a height-adjustable work platform with stair access, the best option for OSHA-compliance is a variable pitch staircase

OSHA Requirements for Guardrail and Safety Railing Compliance .

Feb 1, 2017 . In the interest of time, here is OSHA's official stance on guardrail for general industry applications. OSHA 1910.29(b) contains system requirements that employers must follow to ensure guardrail systems will protect workers from falling to lower levels: 1910.29(b)(1) The top edge height of top rails,..

Plain Text

Covers and/ or guardrails shall be provided to protect personnel from the hazards of open pits, tanks, . have a vertical height of 42 inches nominal from the upper surface of top rail to floor, platform, runway, or ramp level. Nominal height of mid rail is 21 inches. A "standard .. Where are xed stairs required? Fixed Industrial..

Clearing Up the Confusion Surrounding Fall Protection | EHS Today

May 1, 2010 . The top rail must be smooth-surfaced throughout the length of the railing. There must be an intermediate railing approximately halfway between the top rail and the floor. A standard toeboard needs to be 4 inches in vertical height from its top edge to the level of the floor, platform, runway or ramp. It has to be..

WAC 296-24-75011: Railing, toeboards, and cover specifications.

(1) You must ensure that a standard railing consists of top rail, intermediate rail, and posts, and has a vertical height of forty-two inches, plus or minus three inches, from upper surface of top rail to floor, platform, runway, or ramp level and: (a) The top rail must be smooth-surfaced throughout the length of the railing. (b) The..

Guardrails: Design Criteria, Building Codes, & Installation - Buildipedia

Feb 16, 2010 . Height: where required, guardrail height must be a minimum of 42 inches above the leading edge of the tread or walking surface. Opening limitations: . This method can offer several advantages, including the fact that the railing system does not reduce the width of the stair or platform. Also, with standard..

OSHA Standards Analysis for Mezzanine Guardrails - Cisco-Eagle

Nov 9, 2017 . If you have a mezzanine or storage platform custom fabricated, you need to be sure your contractor is complying with OSHA & local safety regulations, . height of top rails, or equivalent guardrail system members, shall be 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level

Guardrail height requirements for construction activities in General .

Apr 17, 2006 . Would the construction employer be in violation of ยง1926.502(b)(1) (Subpart M) of the construction standards, which requires the use of guardrails with a . intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level

2003 IBC SECTION 1012 GUARDS 1012.1 Where required. Guards .

platforms, stairways, ramps and landings which are located more than 30 inches (762 mm) above the floor or grade below. . Exception: Guards are not required for the following locations: 1. On the loading side of . handrail shall have a height not less than 34 inches (864 mm) and not more than 38 inches (965 mm)..

Walking-Working Surfaces OSHA Regulation 29 CFR 1910.21-30

A rail approximately midway between the guardrail and platform, used when required, and secured to the uprights erected along the exposed sides and ends of ... A stair railing shall be of construction similar to a standard railing but the vertical height shall be not more than 34 inches nor less than 30 inches from upper..

Part 21. Guarding of Walking and Working Areas - State of Michigan

R 408.42101 Scope. Rule 2101. This standard pertains to the construction and use of guardrails, stairways, ramps, and runways for the protection of employees during construction operations. It also applies to all stairways that are used in the construction, alteration, repair, including painting and decorating, and demolition..

Know the Requirements for General Industry -- Occupational Health .

Sep 1, 2012 . Under 1910.23(e)(1), OSHA says that a guardrail must have a vertical height of 42 inches nominal from the upper surface of the top rail to floor, platform, runway, or ramp level. "Nominal" simply means that 42 inches has been established as the de facto standard for guardrail height. OSHA allows for..